passion technology in
Professional
Current Transducer
A leading company in electrical measurement, PAS technology engineers the best solutions for energy and mobility,
ensuring that our customers’ systems are optimized, reliable and safe.
Current Transducers
Ultra High Precision
Current Transducer
Model : HPIT-C25-100S
Primary Current : 100A
Conversion Ratio: 1:1000
Accuracy : 0.001%
Power Supply: DC±15V
Ultra High Precision
Current Transducer
Model : HPIT-C25-200S
Primary Current : 200A
Conversion Ratio: 1:1000
Accuracy : 0.001%
Power Supply: DC±15V
Ultra High Precision
Current Transducer
Model : HPIT-C25-400S
Primary Current : 400A
Conversion Ratio: 1:1000
Accuracy : 0.001%
Power Supply: DC±15V
Ultra High Precision
Current Transducer
Model : HPIT-C25-600S
Primary Current : 600A
Conversion Ratio: 1:1000
Accuracy : 0.001%
Power Supply: DC±15V
Ultra High Precision
Current Transducer
Model : HPIT-C25-700S
Primary Current : 700A
Conversion Ratio: 1:1000
Accuracy : 0.001%
Power Supply: DC±15V
Ultra High Precision
Current Transducer
Model : HPIT-C25-1000S
Primary Current : 1000A
Conversion Ratio: 1:1000
Accuracy : 0.001%
Power Supply: DC±15V
High Precision
Current Transducer
Model : HPITM-C23-100S
Primary Current : 100A
Conversion Ratio: 1:2000
Accuracy : 0.01%
Power Supply: DC±15V
High Precision
Current Transducer
Model : HPITM-C23-200S
Primary Current : 200A
Conversion Ratio: 1:2000
Accuracy : 0.01%
Power Supply: DC±15V
High Precision
Current Transducer
Model : HPITM-C23-300S
Primary Current : 300A
Conversion Ratio: 1:2000
Accuracy : 0.01%
Power Supply: DC±15V
High Precision
Current Transducer
Model : HPITM-C32-500S
Primary Current : 500A
Conversion Ratio: 1:2000
Accuracy : 0.01%
Power Supply: DC±15-24V
High Precision
Current Transducer
Model : HPITM-C32-700S
Primary Current : 700A
Conversion Ratio: 1:1750
Accuracy : 0.01%
Power Supply: DC±15-24V
High Precision
Current Transducer
Model : HPITM-C32-1000S
Primary Current : 1000A
Conversion Ratio: 1:2000
Accuracy : 0.01%
Power Supply: DC±15-24V
High Precision
Current Transducer
Model : HPITM-C40-1000S
Primary Current : 1000A
Conversion Ratio: 1:1000
Accuracy : 0.01%
Power Supply: DC±15-24V
High Precision
Current Transducer
Model : HPITM-C40-2000S
Primary Current : 2000A
Conversion Ratio: 1:2000
Accuracy : 0.01%
Power Supply: DC±15-24V
High Precision
Current Transducer
Model : HPITM-C40-3000S
Primary Current : 3000A
Conversion Ratio: 1:5000
Accuracy : 0.01%
Power Supply: DC±15-24V
High Precision
Current Transducer
Model : FIA-C07-50S
Primary Current : 50A
Conversion Ratio: 1:1000
Accuracy : 0.1%
Power Supply: DC±15V
High Precision
Current Transducer
Model : FIA-C07-100S
Primary Current : 100A
Conversion Ratio: 1:1000
Accuracy : 0.1%
Power Supply: DC±15V
High Precision
Current Transducer
Model : FIC-C23-100S
Primary Current : 100A
Conversion Ratio: 1:2000
Accuracy : 0.1%
Power Supply: DC±15V
High Precision
Current Transducer
Model : FIC-C23-200S
Primary Current : 200A
Conversion Ratio: 1:2000
Accuracy : 0.1%
Power Supply: DC±15V
High Precision
Current Transducer
Model : FIC-C23-300S
Primary Current : 300A
Conversion Ratio: 1:2000
Accuracy : 0.1%
Power Supply: DC±15V
High Precision
Current Transducer
Model : FID-C32-500S
Primary Current : 500A
Conversion Ratio: 1:5000
Accuracy : 0.1%
Power Supply: DC±15-24V
High Precision
Current Transducer
Model : FID-C32-600S
Primary Current : 600A
Conversion Ratio: 1:5000
Accuracy : 0.1%
Power Supply: DC±18-24V
High Precision
Current Transducer
Model : FID-C32-1000S
Primary Current : 1000A
Conversion Ratio: 1:5000
Accuracy : 0.1%
Power Supply: DC±15-24V
High Precision
Current Transducer
Model : FIE-C40-50S
Primary Current : 50A
Conversion Ratio: 1:1000
Accuracy : 0.1%
Power Supply: DC±15V
High Precision
Current Transducer
Model : FIE-C40-2000S
Primary Current : 2000A
Conversion Ratio: 1:5000
Accuracy : 0.1%
Power Supply: DC±15-24V
High Precision
Current Transducer
Model : HIE-C40-500S
Primary Current : 500A
Conversion Ratio: 1:5000
Accuracy : 0.2%
Power Supply: DC±15-24V
High Precision
Current Transducer
Model : HIE-C40-1000S
Primary Current : 1000A
Conversion Ratio: 1:5000
Accuracy : 0.2%
Power Supply: DC±15-24V
High Precision
Current Transducer
Model : HIE-C40-2000S
Primary Current : 2000A
Conversion Ratio: 1:5000
Accuracy : 0.2%
Power Supply: DC±15-24V
VOLTAGE TRANSDUCERS
High Precision
Voltage Transducer
Model : FV-C53-50P4O5
Primary Voltage : 50V
Output Signal: 5V
Accuracy : 0.1%
Power Supply: DC±15V
High Precision
Voltage Transducer
Model : FV-C53-100P4O5
Primary Voltage : 100V
Output Signal: 5V
Accuracy : 0.1%
Power Supply: DC±15V
High Precision
Voltage Transducer
Model : FV-C53-200P4O5
Primary Voltage : 200V
Output Signal: 5V
Accuracy : 0.1%
Power Supply: DC±15V
High Precision
Voltage Transducer
Model : FV-C53-500P4O5
Primary Voltage : 500V
Output Signal: 5V
Accuracy : 0.1%
Power Supply: DC±15V
High Precision
Voltage Transducer
Model : FV-C53-1000P4O5
Primary Voltage : 1000V
Output Signal: 5V
Accuracy : 0.1%
Power Supply: DC±15V
High Precision
Voltage Transducer
Model : FV-C53-1500P4O5
Primary Voltage : 1500V
Output Signal: 5V
Accuracy : 0.1%
Power Supply: DC±15V
High Precision
Voltage Transducer
Model : FV-C53-2000P4O5
Primary Voltage : 2000V
Output Signal: 5V
Accuracy : 0.1%
Power Supply: DC±15V
High Precision
Voltage Transducer
Model : EV-C53-50P5O9
Primary Voltage : 50V
Output Signal: 50mA
Accuracy : 0.5%
Power Supply: DC±15-24V
Voltage
Transducer
Model : EV-C53-125P5O9
Primary Voltage : 125V
Output Signal: 50mA
Accuracy : 0.5%
Power Supply: DC±15-24V
Voltage
Transducer
Model : EV-C53-150P5O9
Primary Voltage : 150V
Output Signal: 50mA
Accuracy : 0.5%
Power Supply: DC±15-24V
Voltage
Transducer
Model : EV-C53-250P5O9
Primary Voltage : 250V
Output Signal: 50mA
Accuracy : 0.5%
Power Supply: DC±15-24V
Voltage
Transducer
Model : EV-C53-500P5O9
Primary Voltage : 500V
Output Signal: 50mA
Accuracy : 0.5%
Power Supply: DC±15-24V
Voltage
Transducer
Model : EV-C53-750P5O9
Primary Voltage : 750V
Output Signal: 50mA
Accuracy : 0.5%
Power Supply: DC±15-24V
Voltage
Transducer
Model : EV-C53-1000P5O9
Primary Voltage : 1000V
Output Signal: 50mA
Accuracy : 0.5%
Power Supply: DC±15-24V
Voltage
Transducer
Model : EV-C53-1500P5O9
Primary Voltage : 1500V
Output Signal: 50mA
Accuracy : 0.5%
Power Supply: DC±15-24V
Voltage
Transducer
Model : EV-C53-2000P5O9
Primary Voltage : 2000V
Output Signal: 50mA
Accuracy : 0.5%
Power Supply: DC±15-24V
Digital Current Transducers
Digital Current Transducer
Model : FDIB-C16-100C
Primary Current : DC100A
Output Signal: CAN BUS
Accuracy : 0.1%
Power Supply: DC12V
Digital Current Transducer
Model : FDIB-C16-200C
Primary Current : DC200A
Output Signal: CAN BUS
Accuracy : 0.1%
Power Supply: DC12V
Digital Current Transducer
Model : FDIB-C16-300C
Primary Current : DC300A
Output Signal: CAN BUS
Accuracy : 0.1%
Power Supply: DC12V
Digital Current Transducer
Model : FDIB-C16-500C
Primary Current : DC500A
Output Signal: CAN BUS
Accuracy : 0.1%
Power Supply: DC12V
Digital Current Transducer
Model : FDIB-C16-100M
Primary Current : DC100A
Output Signal: R485
Accuracy : 0.1%
Power Supply: DC12V
Digital Current Transducer
Model : FDIB-C16-200M
Primary Current : DC200A
Output Signal: R485
Accuracy : 0.1%
Power Supply: DC12V
Digital Current Transducer
Model : FDIB-C16-300M
Primary Current : DC300A
Output Signal: R485
Accuracy : 0.1%
Power Supply: DC12V
Digital Current Transducer
Model : FDIB-C16-500M
Primary Current : DC500A
Output Signal: R485
Accuracy : 0.1%
Power Supply: DC12V
switch transducers
Switch Transducer
Model : HJIDK-C31-100P1026
Primary Current : AC100A
Output Signal: Relay(N.O or N.C)
Threshold Point:customize
Accuracy : 1%
Power Supply: DC24V
Switch Transducer
Model : HJIDK-C31-200P1026
Primary Current : AC200A
Output Signal: Relay(N.O or N.C)
Threshold Point:customize
Accuracy : 1%
Power Supply: DC24V
Switch Transducer
Model : HJIDK-C31-300P1026
Primary Current : AC300A
Output Signal: Relay(N.O or N.C)
Threshold Point:customize
Accuracy : 1%
Power Supply: DC24V
Switch Transducer
Model : HJIDK-C31-500P1026
Primary Current : AC500A
Output Signal: Relay(N.O or N.C)
Threshold Point:customize
Accuracy : 1%
Power Supply: DC24V
Switch Transducer
Model : HJIDK-C31-600P1026
Primary Current : AC600A
Output Signal: Relay(N.O or N.C)
Threshold Point:customize
Accuracy : 1%
Power Supply: DC24V
Switch Transducer
Model : HJIDK-C31-800P1026
Primary Current : AC800A
Output Signal: Relay(N.O or N.C)
Threshold Point:customize
Accuracy : 1%
Power Supply: DC24V
Switch Transducer
Model : HJIDK-C31-1000P1026
Primary Current : AC1000A
Output Signal: Relay(N.O or N.C)
Threshold Point:customize
Accuracy : 1%
Power Supply: DC24V
Switch Transducer
Model : HJIDK-C31-1500P1026
Primary Current : AC1500A
Output Signal: Relay(N.O or N.C)
Threshold Point:customize
Accuracy : 1%
Power Supply: DC24V
Keep in Touch!
(+86) 010 89494921
lju@passiontek.com.cn
2930386776
+86 0 138 1011 8920